- Categories
- Top types
- Audio & home theatre
- Cameras & camcorders
- Computer cables
- Computer components
- Computers
- Data input devices
- Data storage
- Networking
- Print & Scan
- Projectors
- Smart wearables
- Software
- Telecom & navigation
- TVs & monitors
- Warranty & support
- other →
- Top brands
- Acer
- AEG
- Aeg-Electrolux
- Canon
- Electrolux
- ESAB
- HP
- LG
- Miller
- Nikon
- Panasonic
- Philips
- Samsung
- Sony
- Texas Instruments
- other →
- Top types
- Infotainment
- Musical instruments
- Video games & consoles
- other →
- Top brands
- Acer
- AEG
- Asus
- Electrolux
- ESAB
- HP
- LG
- Panasonic
- Philips
- Progress
- Samsung
- Sharp
- Sony
- ZANKER
- Zoppas
- other →
- Top types
- Binding machines
- Boards
- Calculators
- Correction media
- Desk accessories & supplies
- Drawing supplies
- Equipment cleansing kit
- Folders, binders & indexes
- Laminators
- Mail supplies
- Paper cutters
- Sorters
- Storage accessories for office machines
- Typewriters
- Writing instruments
- other →
- Top brands
- Bosch
- Canon
- Casio
- Craftsman
- Epson
- Garmin
- GE
- HP
- KitchenAid
- LG
- Panasonic
- Philips
- Samsung
- Sharp
- Texas Instruments
- other →
- Top types
- Bedding & linens
- Cleaning & disinfecting
- Do-It-Yourself tools
- Domestic appliances
- Home décor
- Home furniture
- Home security & automation
- Kitchen & houseware accessories
- Kitchenware
- Lighting
- other →
- Top brands
- AEG
- Aeg-Electrolux
- Bauknecht
- Bosch
- Electrolux
- HP
- Indesit
- LG
- Panasonic
- Philips
- Progress
- Samsung
- Sony
- Whirlpool
- Zanussi
- other →
- Top types
- Bags & cases
- Children carnival costumes
- Clothing care
- Clothing hangers
- Dry cleaners
- Fabric shavers
- Jewelry cleaning machines
- Men's clothing
- Tie holders
- Ultrasonic cleaning equipment
- Watches
- Women's clothing
- other →
- Top brands
- Casio
- Garmin
- Hotpoint
- Huawei
- Indesit
- LG
- Mitsubishi Electric
- Omega
- Philips
- Radio Shack
- Seiko
- Sony
- Uniden
- V7
- Whirlpool
- other →
- Top types
- Air Handlers
- Boom Lifts
- Compact Excavator
- Elevators
- Excavators
- Finishers
- Front End Loaders
- Noise Reduction Machine
- Oxygen Equipment
- Robotics
- Scrubber
- Spreader
- Tractor
- Trash Compactor
- Welding System
- other →
- Top brands
- AEG
- Aeg-Electrolux
- Canon
- Electrolux
- ESAB
- HP
- LG
- Miller
- Nikon
- Panasonic
- Philips
- Samsung
- Sony
- Texas Instruments
- Whirlpool
- other →
- Top types
- Blood pressure units
- Electric toothbrushes
- Epilators
- Feminine hygiene products
- Foot baths
- Hair trimmers & clippers
- Makeup & manicure cases
- Men's shavers
- Personal paper products
- Personal scales
- Shaver accessories
- Skin care
- Solariums
- Teeth care
- Women's shavers
- other →
- Top brands
- AEG
- Aeg-Electrolux
- Bosch
- Canon
- Casio
- Electrolux
- Garmin
- LG
- Panasonic
- Philips
- Samsung
- Sony
- Whirlpool
- Yamaha
- Zanussi
- other →
- Top types
- Hot beverage supplies
- other →
- Top brands
- other →
- Top types
- Cars
- Electric scooters
- Motor vehicle accessories & components
- Motor vehicle electronics
- Motorcycles
- Motorhomes
- Offroad Vehicle
- Scooters
- Utility Vehicle
- other →
- Top brands
- AEG
- Aeg-Electrolux
- Canon
- Casio
- Electrolux
- Garmin
- LG
- Miller
- Panasonic
- Philips
- Samsung
- Sony
- Volvo
- Yamaha
- Zanussi
- other →
- Top types
- Baby bathing & potting
- Baby furniture
- Baby safety
- Baby sleeping & bedding
- Baby travel
- Feeding, diapering & nursing
- Toys & accessories
- other →
- Top brands
- AEG
- Canon
- Electrolux
- Garmin
- HP
- LG
- Miller
- Panasonic
- Philips
- Samsung
- Sony
- Volvo
- Whirlpool
- Yamaha
- Zanussi
- other →
- Top types
- Bicycles & accessories
- Bubble machines
- Camping, tourism & outdoor
- Fitness, gymnastics & weight training
- Martial arts equipment
- Skateboarding & skating
- Smoke machines
- Sport protective gear
- Target & table games
- Water sports equipment
- Winter sports equipment
- other →
- Top brands
- Craftsman
- Daikin
- Emerson
- Epson
- Frigidaire
- Harbor Freight Tools
- HP
- Miele
- Miller
- Omega
- Panasonic
- Philips
- Samsung
- Weider
- Yamaha
- other →
- Top types
- Pet hair clippers
- other →
- Top brands
- Andis
- other →
- Top types
- Home building and Decor
- Kitchen appliances
- Other
- Science and Education
- other →
- Top brands
- other →
- Top types
- Pill Reminder Device
- Stairlifts
- other →
- Top brands
- Alber
- Bruno
- E-PIL
- Minivator
- Savaria
- other →
Download Instructions for use of Dräger Saver CF Series Security Sensors for Free or View it Online on All-Guides.com.
The Drager Saver CF constant flow Emergency Escape Breathing Apparatus allows safe, effective and uncomplicated escape from hazardous environments. Simple to put on and featuring practically automatic operation, this hood-based, positive-pressure breathing device can be used with minimal training.
Brand: Dräger
Category: Security Sensors
Type: Instructions for use for Dräger Saver CF Series
Pages: 2
saver CF Series
Instructions for Use
6
4
5
1
2
3
3700
1
3
5
1
8
402:2003
1 For your safety
● Before using this product, carefully read the Instructions for
● Strictly follow the Instructions for Use. The user must fully
understand and strictly observe the instructions. Use the
product only for the purposes specied in the Intended Use
● Do not dispose of the Instructions for Use. Ensure that they are
retained and appropriately used by the product user.
● Only fully trained and competent users are permitted to use
● Comply with all local and national rules and regulations
● Only trained and competent personnel are permitted to
inspect, repair and service the product. Dräger recommends a
Dräger service contract for all maintenance activities and that
● Properly trained service personnel must inspect and service
this product as detailed in the maintenance section of this
● Use only genuine Dräger spare parts and accessories, or the
proper functioning of the product may be impaired.
● Do not use a faulty or incomplete product, and do not modify
● Notify Dräger in the event of any component fault or failure.
Alert icons are used in this document to provide and highlight text
that requires a greater awareness by the user. A denition of the
!
Indicates a potentially hazardous situation which, if not
!
Indicates a potentially hazardous situation which, if not
avoided, could result in physical injury or damage to the
product or environment. It may also be used to alert against
i
NOTICE
Indicates additional information on how to use the
2 Description
The Dräger saverCF (constant-ow) is an emergency escape
breathing apparatus that provides respiratory protection to escape
from a contaminated or oxygen-decient environment to a safe
The main features of the product are:
● The respiratory protection equipment is contained in a carrying
bag that has a soft or hard case. If the bag is black it indicates
that the bag material has anti-static properties. The bag has a
● The air cylinder is tted inside the carrying bag but has a
pressure gauge (Fig 1, Item 6) that is visible outside the bag.
When the cylinder is full it provides a nominal duration of 10 or
● The cylinder valve/reducer (Fig 1, Item 4) has an automatic
activation device that is operated by removing a two-pronged
locking clip (Fig 1, Item 3). The locking clip is connected by
a strap to a sprung-gate clip (Fig 1, Item 2) that is in turn
connected to a D-ring (Fig 1, Item 1) on the inside of the lid.
This arrangement automatically removes the locking clip as the
carrying bag is opened. When the valve/reducer is activated,
it reduces the cylinder pressure to a medium pressure, and
a preset nozzle inside the valve/reducer provides a constant
● A whistle (Fig 1, Item 5) on the valve/reducer emits a warning
when the cylinder pressure falls to 10 bar to indicate the end of
● The escape hood (Fig 2) has a rubber ring that seals around
the neck, and an internal nose cup that ts over the nose and
● There is an anti-tamper tag (or tags) (Fig 3) tted on the lid of
the carrying bag to allow an inspector to quickly identify that
the bag has not been opened. The soft-case bag has a single
anti-tamper tag (Fig 3, A), and the hard-case bag has two anti-
2.1.1 Air cylinders
The saverCF10 version has a 2 litre aluminium cylinder –
The saverCF15 version has a 3 litre steel cylinder – nominal
The saverCF15 CC version has a 3 litre carbon-composite
2.2 Intended use
When this product is used with an approved air cylinder it
provides the wearer with respiratory protection for escaping from
contaminated or oxygen-decient conditions.The air cylinder used
with this product must be a certied Dräger cylinder; otherwise
the operation of the product may be impaired. Contact Dräger for
The product version marked with the
where the product is stored in, or regularly exposed to, atmospheres
where airborne hydrocarbons or chemical, fuel or oil vapours may
Operating temperature range: -15 °C to 60 °C.
The saverCF15 version (with 3 litre steel cylinder) exceeds
5 kg. This is considered to be unsuitable (as dened in EN 1146)
to be carried by the wearer for more than 8 hours.
The saver CF Series of emergency escape breathing apparatus
conforms to EN 1146:2005, ISO 23269-1:2008 and ISO 23269–
4:2010, and meets the requirement of EC Council Directives PPE
PPE - EC Type examiner: DEKRA EXAM GmbH, Dinnendahlstrasse
PPE (89/686/EEC) – 11B examiner: Lloyd's Register Quality
Assurance (LRQA), 1 Trinity Park, Bickenhill Lane, Birmingham, B37
MED (96/98/EC)/PED (97/23/EC) - Lloyd's RegisterVerication
(LRV), 71 Fenchurch Street, London EC3M 4BS.United Kingdom.
Use in potentially explosive atmospheres
Do not charge the cylinder in a potentially explosive atmosphere.
saver CF Series combinations that are supplied in a black soft-
case bag or hard-case bag have anti-static properties and are type
tested as suitable for use in potentially explosive atmospheres.
The combinations are suitable for use in hazardous areas up to
and including zone 0 and zone 20. The combinations can be used
in atmospheres containing gases of the gas explosion group IIC.
9
saverCF Series combinations that are supplied in an orange
soft-case bag are not suitable for use in potentially explosive
2.5 Explanation of markings and symbols
The date of manufacture of the product is shown on the carrying
is the MED mark of conformity.
!
The time required to allow the wearer to escape to a safe
area must be within capacity of the equipment. When
selecting the type and duration of escape equipment it is
essential to consider potential hazards, storage location
3.1 Preparation for use
WARNING
On receipt of the saverCF from Dräger, the product is
not congured for immediate operational use. The cylinder
automatic activation device is not connected, and the
air cylinder may be discharged. Carry out the following
Immediately following removal of the equipment from its
● If the air cylinder is supplied discharged, see Section 4.2.2 for
● If the air cylinder is supplied fully charged, carry out the
following to connect the cylinder automatic activation device:
a. Grip the loop on the lid of the carrying bag and pull up to
b. Seal the lid along the Velcro fastening strip leaving sufcient
opening to insert a hand and, taking care not to detach the
locking clip from the cylinder valve, connect the sprung-
gate clip (Fig 1, Item 2) to the D-ring (Fig 1, Item 1).
c. Fit the anti-tamper tag(s) and close the lid (Fig 3).
1. Check that the pointer of the cylinder pressure gauge is inside
the green area, and the anti-tamper device on the lid of the
2. Place the neck strap over the head (Fig 4, A) and adjust the
strap until the equipment sits in the centre of the chest.
3. If tted with a waist belt (optional accessory), loop the waist
belt around the waist and then fasten the buckle. Pull the free
end of the belt until the equipment is secure and comfortable.
!
The duration begins from the automatic activation of the
cylinder valve and not from time of putting on the hood.
i
The wearer mustbe able to reach the required area
before the whistle sounds to indicate the end of the rated
1. Grip the loop on the lid of the carrying bag and pull rmly upward
to break the anti-tamper tag(s) and open the lid of the bag
(Fig 4, B). This action removes the locking clip, automatically
activating the cylinder valve and the air supply to the hood.
2. Remove the hood from the carrying bag (Fig 4, C).
3. Place both hands inside the neck seal and carefully stretch the
○ Wearers with spectacles – take care when stretching the
○ Wearers with long hair – tuck the hair inside the hood.
4. Position the nose cup over the nose and mouth and breathe
5. Immediately leave the hazardous area by the shortest and
!
Do not remove the equipment until in a safe area and clear
!
Do not drop or throw down equipment as damage could
6. Once in a safe breathing environment remove the hood. Place
both hands inside the neck seal and carefully stretch the hood
3.4 After use
After any use, the product must be checked and then returned to
the ready-for-use condition. The after use maintenance tasks (see
Section 4.1.2) must be carried out by trained service personnel or
D
D